We present ESCHWEILER modular PRO, the new PC-based generation of analysing systems: compact, fully modular, easy and economical.
With the clear functionality the ESCHWEILER modular PRO is dedicated to serve you. In critical cases even seconds count. We follow this obligation. With its clear and easy handling the ESCHWEILER modular PRO provides fast and accurate results to give you the required informations for your further actions. |
 |
The unlimited flexibility of our new concept is a big advantage for you. Choose only those parameters which are of interest for you - any combination out of 11 parameters is allowed. Even if your workload is changed and new parameters are useful just expand the system with the channels you need.
We save your money for unnecessary investments and costs for operation and maintenance of sensors which are not required. |
 |
|
|
 |
|
 |
| BARCODE READER/NETWORK |
 |
|
Barcode reader
- Input of calibration bag-codes (concentrations)
- Input of encoded patient data
- Input of encoded QC samples
Network (LAN)
- Connection of ESCHWEILER modular PRO to the clinic-internal network via LAN-interface
- Taking over of patient- and QC-data via ODBC (open database connectivity)
|
| |
|
|
 |
| SENSORS |
|
 |

 |
New generation of Biosensors for glucose and lactate determination in whole bloodSensor Chips based on thick-film technology combine:
- Reliable handling
- High storage stability
- Small size Defined quality
- High reproducibility
- Up to 1.000 analyses with one sensor
For more than 5 decades, the name ESCHWEILER has stood for high quality and reliability in blood gas and electrolyte sensors. ESCHWEILER sensors are distinguished by the precision of their measurement and their durability.
- Reduced maintenance
- Replaceable premembraned cartridges
|
| |
|
|
 |
| TOUCHSCREEN |
|
 |
|
Operation of ESCHWEILER modular PRO by touch screen (colour-LCD display / TFT 640 x 480)
- Easy to use, clear step-by-step instructions
- Service- and diagnosis programs for faultless operation
- Data base for patient- and QC-data storage and evaluation
|
| |
|
|
 |
| LIQUID CALIBERATION |
|
 |
|
|
ESCHWEILER modular PRO calibration solutions are delivered in foil packets – easy to handle and individually replaceable.
- Only 4 calibration solutions and a rinse solution to operate an ESCHWEILER modular PRO with complete sensor configuration for analysis of blood gases, electrolytes and metabolites
- Only 2 calibration solutions for analysers with sensor combination “blood gases”, “electrolytes” or “metabolites”
The proven ESCHWEILER blood gas sensor liquid calibration system is also built into the ESCHWEILER modular PRO. Costs for an external calibration gas supply or gas mixing device are eliminated. A mains power lead is enough to make ESCHWEILER modular PRO portable – it can be deployed anywhere at the “point of care”.
|
| |
|
|
 |
| TECHNICAL DATA |
|
 |
| Measured Parameters |
Range |
Resolution |
| pO2 |
0 - 800 mmHg (SI-units selctable) |
0,1 mmHg |
| pCO2 |
5 - 200 mmHg (SI-units selctable) |
0,1 mmHg |
| pH |
6,000 - 8,000 |
0,001 pH |
| total-hemoglobin (tHb) |
5 - 30 g/dl |
0,1 g/dl |
| barometric pressure |
500 - 900 mmHg (SI-units selctable) |
1,0 mmHg |
| Na+ |
100 - 200 mmol/l |
1,0 mmol/l |
| K+ |
2 - 10 mmol/l |
0,1 mmol/l |
| Ca++ |
0,25 2,5 mmol/l |
0,01 mmol/l |
| Li+ |
0,25 2,5 mmol/l |
0,01 mmol/l |
| CI- |
80 - 200 mmol/l |
1,0 mmol/l |
| glucose |
0,5 - 25 mmol/l |
0,1 mmol/l |
| lactate |
0,5 - 20 mmol/l |
0,1 mmol/l |
|
 |
| Input Parameters |
Range |
Resolution |
| patient temperature |
13 - 43 °C |
0,1 °C |
| hemoglobin (tHb) |
0 - 30 g/dl (if not measrued) |
0,1 g/dl |
| fraction of inspired oxygen (FIO2) |
15 - 100 % |
only relvant for AaDO2 |
| respiratory quotient (RQ) |
0,7 - 1,0 |
only relvant for AaDO2 |
|
 |
| Calculated Parameter |
Range |
Resolution |
| hydrogen ion conc. (H+) |
10 - 1000 |
0,1 nmol/l |
actual bicarbonate (HCO3-A) |
10 - 50 |
0,1 mmol/l |
standard bicarbonate (HCO3-S) |
10 - 50 |
0,1 mmol/l |
| base excess (BE) |
-25 - 25 |
0,1 mmol/l |
| standard base excess(SBE) |
-25 - 25 |
1,0 mmol/l |
| total CO2 (T CO2) |
10 - 50 |
0,1 mmol/l |
| buffer base (BB) |
0 - 100 |
0,1 mmol/l |
| O2 saturation of hemoglobin (OO2sat) |
20 - 100 |
0,1 % |
| O2 content or concentration (O2CT) |
0 - 40 |
0,1 % |
| partial O2-pressure at 50% O2-sat (P50) |
10 - 50 |
0,01 mmHg |
| alveolar to arterial oxygen-tension grade (AaDO2) |
0 - 800 |
0,1 mmHg |
| anion gap (A-GAP) |
0 - 99 |
0,1 mmol/l |
| SHUNT |
0 - 50 |
0,1 % |
| acid base status |
relevant diagnosis recorded on printer |
|
| hematocrit (Hct) |
0 - 100 % |
0,1 % |
|
 |
| Data Input |
|
| touchscreen |
|
| barcode reader |
|
|
 |
| Data Output |
|
| display |
color-LCD-display (TFT- 640 x 480) |
| printer |
fast, low-noise thermoprinter |
| interface |
network (LAN), USB |
| data base |
integrated data bases for patient- and QC-data |
|
 |
| Calibration |
|
| automatic calibration |
|
| economy mode |
|
|
 |
| Specimen |
|
| specimen container |
capillary, syringe and others |
| specimen material |
whole blood, serum, plasma / respiratory gas |
|
 |
| Elektrical Data |
|
| voltage |
115 V resp. 230 V |
| frequency |
50/60 Hz |
| ambient temperature |
12 - 32°C |
|
 |
| Dimensions / Weight |
|
| height |
400 mm |
| width |
445 mm |
| depth |
413 mm |
| weight |
appr. 18 kg |
|
Specifications are subject to change without notice.
|
|
| |
|
| |